7 inch Transport Multi-parameter Monitor Medical Patient Monitor With Multi Channel ECG Display

7 inch Transport Multi-parameter Monitor Medical Patient Monitor With Multi Channel ECG Display

Ask Latest Price
Brand Name :BIO
Model Number :PM-9000
MOQ :1 unit
Delivery Time :7 working - days since getting full payment
Payment Terms :Credit card, Paypal, T/T
Supply Ability :1000 units / month
Place of Origin :China
Packaging Details :Carton (39.5*30.5*35cm) 5.3kgs
Multi - Parameter :ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional)
Screen :7" High Resolution Color TFT LCD Display
Safty Standard :GB9706.1
Applicant :Bedside Monitoring, ICU/CCU, Emergency Center, Family Monitoring, Etc
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

7 inch Transport Multi-parameter Monitor Medical Patient Monitor With Multi Channel ECG Display​

Feature

1 The new high-precision module and the new digital blood oxygen technology make the measurement more comprehensive and accurate.
2 High-brightness and high-resolution 7-inch color TFT LCD display, exquisite design, weight only 1.5KG.
3 With ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis.
4

The whole process, full parameter trend chart data, ECG waveform storage

and playback, and power-down save function.

5 Rotary shuttle operation mode, Chinese and English logo buttons, easy to learn and use, simple and intuitive operation.
6 Standards, large fonts, full leads, and trend charts coexist for easy viewing from multiple angles.
7 Built-in removable lithium battery, AC and DC dual purpose, light, energy-saving and environmentally friendly.
8 Suitable for adults, children, newborns; suitable for bedside monitoring, ICU/CCU, operating room, emergency center, family monitoring, etc. in various hospital departments.
9 Optional thermal array recorder (printer).

Standard Configuration

1 PM-9000 7 Inch multi-parameter monitor host 1 unit
2 Built-in rechargeable lithium battery 1 unit
3 Standard five-lead ECG lead connection cable 1 set
4 Standard adult blood pressure cuff 1 set
5 Adult blood oxygen probe 1 set
6 Temperature probe 1 set
7 Power plug cord 1 set
8 Ground wire 1 set
9 User's manual 1 set

Specification

1 ECG Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display
Gain selection: ×1, ×2, ×0.25, ×0.5 four gears
Frequency: 0.5Hz—100Hz
Common mode signal rejection: greater than 70dB
Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files
Heart rate accuracy: ±5 beats/minute
Calibration signal: 1mV (peak value, accuracy ±3%)
ST segment detection: measuring range (-2.0mV---+2.0mV)
Use standard: in line with ANSI/AMI EC13-2002 standard
Response time: 1S
Alarm mode: sound and light alarm
Heart rate alarm preset range: (exceed the preset value alarm)
The upper limit is adjustable between 1-255 times/minute
The lower limit is adjustable between 0-254 times/minute
2 NIBP
Technology: Oscillographic Method
Measurement method: reverse measurement data is more accurate
Unit of measurement: mmHg/Kpa
Overvoltage protection: double safety protection
One measurement time: less than 45S
Pressure range in cuff: 0-250mmHg
Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value
Initial inflation of cuff: 180mmHg (120mmHg for children)
Cuff subsequent inflation: original systolic blood pressure + 30mmHg
Blood pressure measurement range and error:
Systolic blood pressure 60 mmHg~250 mmHg
Average pressure 45 mmHg~235 mmHg
Diastolic blood pressure 40 mmHg~220 mmHg
Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater
Response time: 1S
Alarm mode: sound and light alarm
Alarm prediction range and error: (Alarm when exceeding the preset value)
Systolic blood pressure upper limit 1mmHg~255 mmHg
​Lower limit 0 mmHg ~255 mmHg
Diastolic blood pressure upper limit 1mmHg~255 mmHg
Lower limit 0 mmHg~254 mmHg
Alarm error: ±1 mmHg
Use standard: in line with ANSI/AAMI SP10-2002 standard
3 SPO2 Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency: 20-250 beats/min
Response time: 1S
Alarm mode: sound and light alarm
Alarm range and error: (Alarm exceeding the preset value)
Upper limit 1%~100%
Lower limit 0%~99%
4 TEMP Technology: Highly sensitive thermistor probe
Body temperature measurement range: 20℃-- 45℃
Resolution: 0.1%
Body temperature accuracy: ±1℃
Response time: 1S
Alarm mode: sound and light alarm
Alarm preset range and error: (Alarm when exceeding the preset value)
The upper limit is adjustable between 20.1℃-- 45.5℃
The lower limit is adjustable between 20℃ and 45.4℃
Alarm error: ±1℃
5 RESP Respiration rate range: 0-60 times/min
Accuracy: ±1rpm
Response time: 1S
Gain options: ×1, ×2, ×4, ×0.5 four gears
Alarm mode: sound and light alarm
Alarm preset range and error: (Alarm when exceeding the preset value)
The upper limit is adjustable between 10-100 times/minute
The upper limit is adjustable between 0-99 times/minute
Alarm error: ±1rpm
6 Printer(Optonal) Specifications: Dual-channel thermal array recorder
Printing method: real-time or event trigger recording waveform, text
Resolution: Horizontal: 400dpi / Vertical: 800dpi
Note: Date (year/month/day)/time (24 hours)
Optional wall bracket, mobile bracket, backpack
7 System

Display: 7 inch TFT true color LCD display

Battery (optional): LeadAcid fully sealed maintenance-free battery
Safety standard: lec601-1 (International GB9706.1)